TS60温度冲击试验箱 技术参数 1.2 Technical data TS 60 Test chamber Material stainless steel, Material No. 1.4301 Basket dimensions Height approx. 370 mm Width approx. 380 mm Depth approx. 430 mm Contents approx. 60 l Max. weight of specimen approx. 20 kg Exterior housing Dimensions for installation and operation Height approx. 2330 mm with protective pipe for spindle Width approx. 875 mm without colour touch panel Depth without colour touch panel approx. 1970 mm Depth with colour touch panel approx. 2210 mm Required clearances for test cabinet Height approx. 1895 mm Width approx. 810 mm Depth approx. 1860 mm (door dismantled) Exterior finish Powder coating, two-coloured grey white RAL 9002 violet blue RAL 5000 Door manual, lockable door, hinge on left Door window approx. 355 x 355 mm 1.3 Installation drawing D1 Entry port installed in basic design D2 Further entry port in the ceiling (option) 1 Main switch panel 2 Control unit >Colour Touch Panel< 3 Controlpad* 4 Connection for test space drain 5 Electrical connection, cable length approx. 3.5m 6 Door with window 8 Connection for cooling water inlet (option) 9 Connection for cooling water outlet (option) 12 Pressure compensation opening LN2 (option) 14 Connection for compressed air / nitrogen inert (option) 18 Volume compensation system $ Safety clearance to VDE 100 Part 729 ~ Overall dimension 1.4 Equipment Basket Stainless steel, Material No. 1.4301, Max. load 20 kg, state indicator via easily visible pilot lamps, drive via electrical motor and ball screw spindle. Transfer time, total < 10 sec. Shelf 1 pc. stainless steel, max. load 2.5 kg, 8 mm mesh, with fittings for supporting shelves at a distance of 20 mm in the basket, maximum number of shelves 8 pcs. Port approx. 80 mm ?, stainless steel Refrigeration unit Semi-hermetic refrigeration unit, air-cooled version Chlorine-free refrigerants R404A and R23 without ozone-reducing potential are used. Interfaces ? 1 Ethernet interface (100/10 Megabit) for integration into network ? 1 USB interface for direct documentation of measuring data via USB stick (USB stick is not included) or as printer interface Digital I/O ? 4 digital outputs for control of customer-provided devices by means of potential-free contacts, load max. 24 V-DC, 0,5 A ? 4 digital inputs for feedback of customer provided devices, load max. 24 V-DC, approx. 30 mA 1.5 Performance data Changeover time between hot/cold chamber < 10 sec. Temperature ranges - Hot chamber - Cold chamber from +50 °C to +220 °C from -80 °C to +70 °C Hot or cold chambers can be used as single temperature chambers. Temperature constancy, in time ±0.3 K to ±1.0 K Temperature homogeneity, spatial depending on adjusted set point value in the temperature range -65 °C to +200 °C ±0.5 K to ±2.0 K Heat up speed of hot chamber as per IEC 60068-3-5 17 K/min. Cool down speed of cold chamber as per IEC 60068-3-5 3.7 K/min. Heat up speed of cold chamber as per IEC 60068-3-5 3.2 K/min. Alternating temperature tests: MIL 883 E Method 1010.7, degree of intensity D with 4.5 kg ICs distributed over 2 shelves, measurement in specimen adaptation time < 15 min. Pre temperature conditioning Temperature change rates can be increased by selecting higher/lower temperatures in the hot/cold chamber Calibration values -40 °C cold chamber and +125 °C hot chamber